  • 本篇論文使用Android平台開發一套可以使用內建相機即時量測臉部心率變化的APP應用程式。透過快速傅立葉轉換,我們可以將處理過的影像訊號轉換成功率頻譜,從頻譜中我們可以尋找最大的峰值再轉換成心率。在固定量測區域 (Region of Interest, ROI)的靜態實驗中,在外加光源和一般環境光源的條件下,量測到的心率準確率分別為97.98%和98.01%。


    In this thesis, we developed an Android APP to detect the heart rate in real time using built-in camera on the smartphone. The green-color signal of camera is transformed into the power spectrum by Fast Fourier Transform (FFT). Then, we find out the maximum peak and calculate the heart rate value from the power spectrum. In the experiment results, the average accuracy rate is 97.98% and 98.01% on an adding light environment and the normal light environment separately.

    摘要 I Abstract II 誌謝 III 圖目錄 VI 表目錄 VII 第一章 緒論 1 1.1 研究動機與目的 1 1.2 論文架構 4 第二章 研究背景與論文回顧 5 2.1 心電訊號量測 5 2.2 其他心率量測方法 6 第三章 系統設計與方法 8 3.1 心率APP程式基本架構 8 3.2 影像處理 10 3.2.1 影像處理程序與演算法 10 3.2.2 正規化 11 3.3 快速傅立葉 14 第四章 實驗結果與討論 16 4.1 MATLAB影像區域分析實驗 16 4.1.1 實驗設計 16 4.1.2 實驗配備 16 4.1.3 受測人員 17 4.1.4 影像分析處理 17 4.1.5 實驗結果與分析一 18 4.2 Android心率APP與DASH 3000比較實驗 28 4.2.1 實驗設計 28 4.2.2 實驗配備 29 4.2.3 受測人員 30 4.2.4 影像處理分析 30 4.2.5 實驗結果與準確率分析 31 4.3 Android心率APP與“我的心跳”APP比較 33 4.3.1 實驗設計 33 4.3.2 實驗配備 33 4.3.3 受測人員 35 4.3.4 實驗結果與準確率分析 35 第五章 結論與未來展望 37 參考資料 38 附錄壹外加光源下的APP準確度實驗數據 41 附錄貳一般環境光源APP準確度實驗數據 49

    [1] H. Liu, Y. Wang, and L. Wang “Review of Non-Contact, Low-Cost Physiological Information Measurement based on Photoplethysmographic Imaging” Conference of the IEEE EMBS, pp. 2089-2090, 2012
    [2] J. A. C. Patterson, D. G. McIlwraith, and G. Z. Yang, "A Flexible, Low Noise Reflective PPG Sensor Platform for Ear-Worn Heart Rate Monitoring,” in Wearable and Implantable Body Sensor Networks. Sixth International Workshop on, 2009, pp. 286-291, 2009.
    [3] S. Kunsoo, K. Younho, B. Sanggon, P. Kunkook, and K. Sookwan, “A Novel Headset with a Transmissive PPG Sensor for Heart Rate Measurement,” in 13th International Conference on Biomedical Engineering. vol. 23, pp. 519-522, 2009.
    [4] D. W. Holdsworth,C. J. D.Norley, R. Frayne,D. A. Steinmanand B. K.Rutt,“Characterization of common carotid artery blood-flow waveforms in normal human subjects,”Physiol. Meas., vol. 20, pp. 219-240, 1999,.
    [5] J. Geisheimer, E. F. Greneker III,“A non-contact lie detector using radar vital signs monitor (RVSM) technology,”IEEE Aerospace and Electronics Systems Magazine.vol 16, no. 8, pp. 10-14, 2001.
    [6] M. Z. Poh, N. C. Swenson, and R. W. Picard, “Motion-TolerantMagnetic Earring Sensor and Wireless Earpiece for Wearable Photoplethysmography,”Information Technology in Biomedicine, IEEE Transactions on, vol. 14, pp. 786-794, 2010.
    [7] M. Garbey, A. Merla, and I. Pavlidis, “Estimation of blood flow speed and vessel location from thermal video,” in Proc. 2004 IEEE Computer Society Conf. Computer Vision and Pattern Recognition, vol. 1, pp. 356–363, 2004,.
    [8] N. Sun, M. Garbey, A. Merla, and I. Pavlidis, “Imaging the cardiovas-cular pulse,” in IEEE Comput. Soc. Conf. Computer Vision and Pattern ecognition, pp. 416–421, 2005.
    [9] I. Pavlidis and J. Levine, “Monitoring of periorbital blood flow rate through thermal image analysis and its application to poly-graph testing,”in Proc. 23rd Annu. Int. Conf. IEEE Engineering in Medicine and Biology, Istanbul, Turkey, vol. 3, pp.2826–2829, 2001.
    [10] M. Garbey, N. Sun, A. Merla and I.Pavlidis“Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery”IEEE Transactions On Biomedical Engineering, vol. 54, no. 8, pp.1418-1426, 2007.
    [11] 游賀中, “以可以程式化系統單晶片開發一套穿戴式的心率量測系統,” 2011.
    [12] K. Aminian, X. Thouvenin, P. Robert, J. Seydoux, and L. Girardier,”A piezoelectric belt for cardiac pulse and respiration measurements on small mammals,”inProc. 14th Annu. Int. Conf. IEEE Engineering in Medicine and Biology Society, pp. 2663–2664, 1992.
    [13] M. Z. Poh, D. J. McDuff and R. W. Picard, “Advancements in noncontact, multiparameter physiological measurements using a webcam,”IEEE Trans. Biomed. Eng., vol. 58, no. 1, pp. 7 -11, 2010.
    [14] Kwon, S., Kim, H., and Kwang, S. P., “Validation of Heart Rate Extraction Using Video Imaging on a Built-in Camera System of a Smartphone,”IEEE International Conference on Engineering Medicine and Biology Society, pp. 2174-2177, 2012
    [15] A.V Oppenheim and R.W. Schafer, “Discrete-time Signal Processing”, Pretice-Hall, 1989
    [16] H. M. Lee, D. J., Kim, H. K. Yang, K. S., Kim, J.W., Lee, E. J., Cha, and K. A., Kim, “Human Sensibility Evaluation Using Photoplethysmogram (PPG),”IEEE International Conference on Complex Intelligent and Software Intensive Systems, pp. 149-153, 2009.
    [17] J.W. Cooley, J.W. Tukey, “An algorithm for machine computation of complex Fourier series”, Mathematics Computation, pp. 297-301, 1965.

    QR CODE