研究生: |
賴明緯 Ming-Wei Lai |
---|---|
論文名稱: |
光耦合器在矽基掃頻式光學同調斷層掃描術的訊號和雜訊之效應 Optical Coupler Effect in Signal and Noise for Silicon-based Swept-Source Optical Coherence Tomography |
指導教授: |
徐世祥
Shih-Hsiang Hsu 林保宏 Pao-hung Lin |
口試委員: |
蔡孟燦
Meng-Tsan Tsai 周錫熙 H.-H. Chou 林保宏 Pao-hung Lin 徐世祥 Shih-Hsiang Hsu |
學位類別: |
碩士 Master |
系所名稱: |
電資學院 - 光電工程研究所 Graduate Institute of Electro-Optical Engineering |
論文出版年: | 2021 |
畢業學年度: | 109 |
語文別: | 中文 |
論文頁數: | 83 |
中文關鍵詞: | 掃頻式光學同調斷層掃描 、光學同調斷層掃描 、光耦合器 、矽基 、訊號和雜訊 |
外文關鍵詞: | Signal and Noise |
相關次數: | 點閱:463 下載:0 |
分享至: |
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報 |
[1] J. T. Vaughan et al., "Current and Future Trends in Magnetic Resonance Imaging (MRI)," in 2006 IEEE MTT-S International Microwave Symposium Digest, 11-16 June 2006 2006, pp. 211-212, doi: 10.1109/MWSYM.2006.249451.
[2] C. F. Beckmann and S. M. Smith, "Probabilistic independent component analysis for functional magnetic resonance imaging," (in eng), IEEE Transactions on Medical Imaging, vol. 23, no. 2, pp. 137-52, Feb 2004, doi: 10.1109/tmi.2003.822821.
[3] P. J. L. Riviere, P. Vargas, G. Fu, and L. J. Meng, "Accelerating X-ray fluorescence computed tomography," in 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 3-6 Sept. 2009 2009, pp. 1000-1003, doi: 10.1109/IEMBS.2009.5333568.
[4] V. Daeichin, K. Kooiman, I. Skachkov, J. G. Bosch, A. F. W. v. d. Steen, and N. d. Jong, "Optimization of ultrasound contrast agent for high frequency ultrasound molecular imaging using subharmonic oscillation," in 2014 IEEE International Ultrasonics Symposium, 3-6 Sept. 2014 2014, pp. 1766-1769, doi: 10.1109/ULTSYM.2014.0438.
[5] M. Rajadhyaksha, "Confocal microscopy of skin cancers: translational advances toward clinical utility," (in eng), Annual International Conference of the IEEE Engineering in Medicine and Biology Society, vol. 2009, pp. 3231-3, 2009, doi: 10.1109/iembs.2009.5333600.
[6] S. F. Silva, A. Batista, J. P. Domingues, M. J. Quadrado, and M. Morgado, "Fluorescence lifetime microscope for corneal metabolic imaging," in 2015 IEEE 4th Portuguese Meeting on Bioengineering (ENBENG), 26-28 Feb. 2015 2015, pp. 1-5, doi: 10.1109/ENBENG.2015.7088878.
[7] D. G. Winters, J. Speirs, E. Block, R. A. Bartels, and J. A. Squier, "High-Speed Two-Dimensional Multiphoton Microscope using Spatial Modulation," in Conference on Lasers and Electro-Optics 2012, San Jose, California, 2012/05/06 2012: Optical Society of America, in OSA Technical Digest, p. JW3G.1.
[8] W. Drexler and J. G. Fujimoto, Optical coherence tomography: technology and applications. Springer Science & Business Media, 2008.
[9] A. F. Fercher, W. Drexler, C. K. Hitzenberger, and T. Lasser, "Optical coherence tomography-principles and applications," Reports on progress in physics, vol. 66, no. 2, p. 239, 2003.
[10] R. Leitgeb, C. Hitzenberger, and A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Optics express, vol. 11, no. 8, pp. 889-894, 2003.
[11] B. I. Akca et al., "Toward spectral-domain optical coherence tomography on a chip," IEEE journal of selected topics in quantum electronics, vol. 18, no. 3, pp. 1223-1233, 2011.
[12] G. Yurtsever, N. Weiss, J. Kalkman, T. G. van Leeuwen, and R. Baets, "Ultra-compact silicon photonic integrated interferometer for swept-source optical coherence tomography," Optics letters, vol. 39, no. 17, pp. 5228-5231, 2014.
[13] M. E. Brezinski, Optical coherence tomography: principles and applications. Elsevier, 2006.
[14] B. Bouma, Handbook of optical coherence tomography. CRC Press, 2001.
[15] M. A. Choma, M. V. Sarunic, C. Yang, and J. A. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Optics express, vol. 11, no. 18, pp. 2183-2189, 2003.
[16] S. Murali and J. Rolland, "Dynamic-focusing microscope objective for optical coherence tomography," in International Optical Design Conference, 2006: Optical Society of America, p. MD5.
[17] S. Yun, G. Tearney, J. De Boer, and B. Bouma, "Motion artifacts in optical coherence tomography with frequency-domain ranging," Optics Express, vol. 12, no. 13, pp. 2977-2998, 2004.
[18] H. C. Hendargo, R. P. McNabb, A.-H. Dhalla, N. Shepherd, and J. A. Izatt, "Doppler velocity detection limitations in spectrometer-based versus swept-source optical coherence tomography," Biomedical optics express, vol. 2, no. 8, pp. 2175-2188, 2011.
[19] K. Neuhaus et al., "Performance review of multiple reference versus time domain optical coherence tomography," IEEE Photonics Journal, vol. 10, no. 3, pp. 1-14, 2018.
[20] P. Li, Y. He, and H. Ma, "Spectral-domain optical coherence tomography and applications for biological imaging," in 2006 International Symposium on Biophotonics, Nanophotonics and Metamaterials, 2006: IEEE, pp. 222-225.
[21] Z. Chen, "Fourier domain functional optical coherence tomography," in Frontiers in Optics, 2005: Optical Society of America, p. FWA1.
[22] T. Fountoukidou, P. Raisin, D. Kaufmann, J. Justiz, R. Sznitman, and S. Wolf, "Motion-invariant SRT treatment detection from direct M-scan OCT imaging," International journal of computer assisted radiology and surgery, vol. 13, no. 5, pp. 683-691, 2018.
[23] T. Latychevskaia, "Lateral and axial resolution criteria in incoherent and coherent optics and holography, near-and far-field regimes," Applied optics, vol. 58, no. 13, pp. 3597-3603, 2019.
[24] S. Bliven. [Online]. Available: https://commons.wikimedia.org/wiki/File:Airy_ disk_spacing_near_Rayleigh_criterion.png.
[25] H. Imam, "Microscopy/ophthalmology/supercontinuum lasers: supercontinuum light empowers research, biomedicine," Biooptics world, 2014.
[26] D. W. Piston, "Choosing objective lenses: the importance of numerical aperture and magnification in digital optical microscopy," The Biological Bulletin, vol. 195, no. 1, pp. 1-4, 1998.
[27] H. M. Subhash, "Full-field and single-shot full-field optical coherence tomography: a novel technique for biomedical imaging applications," Advances in Optical Technologies, vol. 2012, 2012.
[28] "Wavelengths used for cold laser therapy," Coldlasers.org, 2020.
[29] J. S. a. M. Y. Jamro, "Optical fiber communications: principles and practice, 3rd ed," Financial Times/Prentice Hall, 2009.
[30] H. Yamada, T. Chu, S. Ishida, and Y. Arakawa, "Optical directional coupler based on Si-wire waveguides," IEEE photonics technology letters, vol. 17, no. 3, pp. 585-587, 2005.
[31] A. Agrawal, T. J. Pfefer, P. D. Woolliams, P. H. Tomlins, and G. Nehmetallah, "Methods to assess sensitivity of optical coherence tomography systems," Biomedical optics express, vol. 8, no. 2, pp. 902-917, 2017.
[32] M. E. Brezinski et al., "Optical coherence tomography for optical biopsy: properties and demonstration of vascular pathology," Circulation, vol. 93, no. 6, pp. 1206-1213, 1996.
[33] B. R. Biedermann, W. Wieser, C. M. Eigenwillig, and R. Huber, "Recent developments in Fourier Domain Mode Locked lasers for optical coherence tomography: Imaging at 1310 nm vs. 1550 nm wavelength," Journal of biophotonics, vol. 2, no. 6‐7, pp. 357-363, 2009.
[34] F. Lexer, C. K. Hitzenberger, A. Fercher, and M. Kulhavy, "Wavelength-tuning interferometry of intraocular distances," Applied optics, vol. 36, no. 25, pp. 6548-6553, 1997.
[35] G. Hausler and M. W. Lindner, "" Coherence radar" and" spectral radar"-new tools for dermatological diagnosis," Journal of biomedical optics, vol. 3, no. 1, pp. 21-31, 1998.
[36] [Online]. Available: https://www.thorlabs.com/thorproduct.cfm?partnumber= PDB450C-AC.
[37] U. Thorlabs Inc. (New Jersey, 2020. [Online]. Available: http://www.thorlabs.com/.
[38] "Scotch Tape." [Online]. Available: https://www.tedpella.com/tape_html/tape.htm#_ 16089-6.