中文關鍵詞: 雙變壓器主動箝位零電壓切換順向式轉換器非線性轉換比。
外文關鍵詞: Active clamp, zero-voltage-switching, forward converter, non-linear conversion ratio
相關次數: 點閱:185下載:15
分享至:
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報

本文提出一具非線性轉換比之雙變壓器主動箝位零電壓切換順向式轉換器,其架構以主動箝位零電壓切換順向式轉換器為基礎,利用雙變壓器共生之方式將兩組單晶電源轉換器組合。此架構之優點為變壓器與輸出整流二極體在選擇上僅需以一半的負載功率作為考量;另外轉換器亦僅需兩個切換開關,因而可降低轉換器控制複雜度,且兩組切換開關皆操作於零電壓切換,可提高轉換器效率。本文透過次級側整流架構的改變,可使電路同時有寬輸入電壓範圍與高降壓比的特性,並讓轉換器能有更高的開關利用率。本文將分析與討論電路之動作原理及設計,並實作一台輸入直流電壓130~230 V、輸出24 V/8 A之具非線性轉換比雙變壓器主動箝位順向式轉換器,以驗證理論分析與實測結果。


This thesis presents a two-transformer active-clamping zero-voltage-switching (ZVS) forward converter with non-linear conversion ratio. The proposed topology is mainly composed of two active-clamping converters. The advantage of this topology is that the output power can be shared by two transformers. Therefore, the stresses of the output rectifier can be decreased. Only two switches are required. The circuit complexity is thus reduced. The leakage inductor of the transformer or an additional resonant inductor is employed to achieve ZVS during the dead times, and therefore the converter efficiency is improved. By changing circuit architecture of the secondary side, the presented converter is more suitable for wide input voltage range, high step-down ratio feature and higher switch utilization. The operation principles and design considerations of the proposed converter are analyzed and discussed in detail. The input voltage is from 130 V to 230 V, the output voltage is 24 V, and the output current is 8 A. Theoretical analyses are verified with the experimental results.

摘 要 Abstract 目 錄 圖目錄 表目錄 符號索引 第一章 緒論 1.1 研究動機 1.2 研究內容 1.3 論文大綱 第二章 主動箝位順向式轉換器說明與分析 2.1 主動箝位順向式轉換器架構說明 2.1.1 穩態分析 2.1.2 動作原理 2.2 非線性轉換比主動箝位順向式轉換器架構說明 2.2.1 穩態分析 2.2.2 動作原理 2.3 優缺點探討 第三章 非線性轉換比之雙變壓器主動箝位順向式轉換器動作原理 3.1 電路架構說明 3.2 穩態分析 3.3 動作原理 3.4 本論文架構探討 第四章 電路參數設計 4.1 電路設計 4.1.1 電路規格 4.1.2 變壓器設計 4.1.3 功率開關設計 4.1.4 諧振電感設計 4.1.5 箝位電容設計 4.1.6 輸出電感設計 4.1.7 輸出電容設計 4.1.8 整流二極體選擇 4.2 控制器控制方式 4.2.1 控制IC TL494 4.2.2 開關驅動信號設計 4.2.3 隔離驅動電路設計 第五章 實驗結果與分析 5.1 實測波形數據 5.2 轉換器效率量測 第六章 總論與未來展望 6.1 總論 6.2 未來展望 參考文獻

[1]江炫樟編譯,電力電子學,第三版,台北:全華圖書,2008年。(原著 Mohan, Undeland, Robbins, 2003)
[2]梁適安,高頻交換式電源供應器原理與設計,第二版,台北:全華圖書,1995年。(原著 G. Chryssis, 1984)
[3]EPARC,電力電子學綜論,第二版,台北:全華圖書,2008年。
[4]R. Watson, F. C. Lee, and G. C. Hua, “Utilization of an active-clamp circuit to achieve soft switching in flyback converters,” IEEE Transactions on Power Electronics, vol. 11, no. 1, pp. 162-169, Jan. 1996.
[5]梁適安,交換式電源供給器之理論與實務設計,修訂版,台北:全華圖書,2011年。
[6]J. Feng, Y. Hu, W. Chen, and C. C. Wen, “ZVS analysis of asymmetrical half-bridge converter,” in Proc. IEEE Power Electronics Specialists Conference, 2001, pp. 243-247.
[7]F. S Tsai and F. C. Lee, “A complete DC characterization of a constant-frequency, clamped-mode, series resonant converter,” in Proc. IEEE Power Electronics Specialists Conference, 1988, pp. 987-996.
[8]A. K. S. Bhat, “Analysis and design of a modified series resonant converter,” IEEE Transactions on Power Electronics, vol. 8, no. 4, pp. 423-430, Oct. 1993.
[9]R. Liu, L. Batarseh, and C. Q. Lee, “Comparison of performance characteristics between LLC-type and conventional parallel resonant converters,” IEE Electronics Letters, vol. 24, no. 4, pp. 1510-1511, Nov. 1988.
[10]L. Yan, L. Wenduo, L. Bing, and D. J. Wyk, “Design of integrated passive component for a 1 MHz 1 kW half-bridge LLC resonant converter,” in Proc. IEEE Industry Applications Conference, 2005, pp. 2223-2228.
[11]H. K. Ji and H. J. Kim, “Active clamp forward converter with MOSFET synchronous rectification,” in Proc. IEEE Power Electronics Specialists Conference, 1994, pp. 895-901.
[12]A. Acik and I. Cadirci, “Active clamp ZVS forward converter with soft-switched synchronous rectifier for maximum efficiency operation,” in Proc. IEEE Power Electronics Specialists Conference, 1998, pp. 1237-1242.
[13]G. Stojcic, F. C. Lee, and S. Hiti, “Small signal characterization of active clamp PWM converters,” in Proc. 11th High Freq. Power Conversion Conference, 1996, pp. 52-62.
[14]R. Watson, F. C. Lee, and G. C. Hua, “Utilization of an active-clamp circuit to achieve soft switching in flyback converters,” IEEE Transactions on Power Electronics, vol. 11, no. 1, pp. 162-169, Jan. 1996.
[15]B. Carsten, “Design techniques for transformer active reset circuit at high frequencies and power levels,” in Proc. 5th High Freq. Power Conversion Conference, 1990, pp. 235-245.
[16]Q. M. Li, F. C. Lee, and M. M. Jovanovic, “Large-signal transient analysis of forward converter with active-clamp reset,” IEEE Transactions on Power Electronics, vol. 17, no. 1, pp.15-24, Jan. 2002.
[17]H. K. Yoon, S. K. Han, J. S. Park, G. W. Moon, and M. J. Youn, “Zero-voltage switching two-transformer full-bridge PWM converter with lossless diode-clamp rectifier for PDP sustain power module,” IEEE Transactions on Power Electronics, vol. 21, no. 5, pp. 1243-1252, Sept. 2006.
[18]H. K. Yoon, E. S. Choi, S. K. Han, G. W. Moon, and M. J. Youn, “Zero-voltage and zero-current switching two transformer full-bridge converter using the output voltage doubler,” in Proc. IEEE Power Electronics and Motion Control Conference, 2006, pp. 1-5.
[19]G. B. Koo, G. W. Moon, and M. J. Youn, “Analysis and design of phase shift full bridge converter with series-connected two transformers,” IEEE Transactions on Power Electronics, vol. 19, no. 2, pp. 411-419, Mar. 2004.
[20]Y. H. Leu and C. L. Chen, “Analysis and design of the two-transformer asymmetrical half-bridge converter,” in Proc. IEEE Power Electronics Specialists Conference, 2002, pp. 943-948.
[21]T. Jin. W. Zhang, A. Azzolini, and K. M. Smedley, “A new interleaved forward converter with inherent demagnetizing feature,” in Proc. IEEE Industry Applications Conference, 2005, pp. 625-630.
[22]B. R .Lin, H. K, Chiang, and C. C. Chen, “Analysis of a zero-voltage switching converter with two transformers,” IEEE Transactions on Circuits and Systems II: Express Briefs, vol. 53, no. 10, pp. 1088-1092, Oct. 2006.
[23]B. R. Lin, H. K.Chiang, C. E. Huang, K. C. Chen, and D. Wang, “Analysis of an active clamp forward converter,” in Proc. IEEE International Conference on Power Electronics and Drives Systems, 2005, pp. 140-145.
[24]B. Axelrod, Y. Berkovich, and A. Ioinovici, “Switched- capacitor/switched-inductor structures for getting transformer less hybrid DC-DC PWM converters,” IEEE Transactions on Circuits and Systems I: Regular Papers, vol. 55, no. 2, pp. 687-696, Mar. 2008.
[25]Q. M. Li, F. C. Lee, and M. M. Jovanovic, “Large-signal transient analysis of forward converter with active-clamp reset,” IEEE Transactions on Power Electronics, vol. 17, no. 1, pp. 15-24, Jan. 2002.
[26]R. Torrico-Bascop and I. Barbi, “A double ZVS-PWM active-clamping forward converter: analysis, design and experimentation,” IEEE Transactions on Power Electronics, vo1. 16, no. 6, pp. 745-751, Nov. 2001.
[27]B. Axelrod, Y. Berkovich, and A. Ioinovici, “Transformerless dc-dc converters with a very high dc line-to-load voltage ratio,” in Proc. IEEE International Symposium on Circuits and Systems, 2003, pp. 435-438.
[28]盛瀅瑾,非線性轉換比主動箝位順向式轉換器之研製,國立台灣科技大學電子工程研究所博士論文,2014年。
[29]TDK Corporation of America, “Ferrite for Switching Power Supplies,” Datasheet, 2011.
[30]林景源,雙變壓器主動箝位順向式與返馳式轉換器,國立台灣科技大學電子工程研究所博士論文,2007年。
[31]蕭家斌,雙變壓器主動箝位順向式轉換器之研製,國立台灣科技大學電子工程系研究所碩士論文,2011年。
[32]TI, “TL494 Pulse Width Modulation Control Circuits,” Datasheet, 2005.
[33]Avago, “2.5 Amp Output Current IGBT Gate Drive Optocoupler,” Datasheet, 2008.

無法下載圖示 全文公開日期 2019/07/15 (校內網路)
全文公開日期 本全文未授權公開 (校外網路)
全文公開日期 本全文未授權公開 (國家圖書館:臺灣博碩士論文系統)