簡易檢索 / 詳目顯示

研究生: 呂懋斌
Mao-Bin Lu
論文名稱: 具預測型控制及自調式弱磁控制的內藏式永磁同步電動機驅動系統的研製
Design and Implementation of a Predictive Controller and Auto-tuning Flux Weakening Control for an IPMSM Drive System
指導教授: 劉添華
Tian-Hua Liu
口試委員: 李永勳
Yuang-Shung Lee
楊勝明
Sheng-Ming Yang
楊宗銘
Chung-Ming Young
學位類別: 碩士
Master
系所名稱: 電資學院 - 電機工程系
Department of Electrical Engineering
論文出版年: 2016
畢業學年度: 104
語文別: 中文
論文頁數: 103
中文關鍵詞: 內藏式永磁同步電動機弱磁控制預測型控制器
外文關鍵詞: interior permanent magnet synchronous motor, flux weakening control, predictive controller.
相關次數: 點閱:427下載:0
分享至:
查詢本校圖書館目錄 查詢臺灣博碩士論文知識加值系統 勘誤回報
  • 本文探討內藏式永磁同步電動機驅動系統的研製。首先,探討預測型速度控制器的設計,其次提出不須參數的自調式弱磁控制。利用回授電動機的電壓,當電壓高於直流鏈電壓時,即時調整電流超前角的大小,達成自調式的弱磁控制。
    文中使用德州儀器公司所生產的TMS320F28335數位信號處理器,執行預測型速度控制器及弱磁控制等運算。實測結果說明本文所提方法的正確性及可行性。本文所提的驅動系統包括寬廣的控速範圍,快速的暫態響應,良好的加載響應,及良好的追蹤響應。


    The thesis investigates the design and implementation of an interior permanent magnet synchronous motor drive system. First, a predictive speed controller design is proposed. Next, a auto-tuning flux weakening control, which doesn’t require any motor parameters, is proposed. The voltage of the motor is feedback. When the motor voltage is higher than the dc link voltage, an advance current angle is online adjusted to execute the auto-tuning flux-weakening control.
    A digital signal processor, TMS320F28335, is used to execute the speed controller and flux-weakening control. Experimental results validate the correctness and feasibility of the proposed methods. The proposed system includes a wide adjustable speed range, fast transient response, good load response, and good tracking response.

    中文摘要 I Abstract II 目錄 III 圖目錄 VI 表目錄 X 符號索引 XI 第一章 緒論 1 1.1 研究動機 1 1.2文獻回顧 3 1.3目的 6 1.4大綱 7 第二章 內藏式永磁同步電動機 8 2.1簡介 8 2.2結構與特性 8 2.3數學模型 13 2.4永磁同步電動機的轉矩控制 20 第三章 脈波寬度調變與閉迴路控制 21 3.1簡介 21 3.2空間向量脈波寬度調變 21 3.3閉迴路控制 28 3.3.1直接轉矩控制 28 3.3.2向量控制 28 第四章 控制器設計 30 4.1簡介 30 4.2速度估測器 31 4.3預測型控制器設計 35 4.3.1基本原理 35 4.3.2預測型速度控制器 37 第五章 閉迴路驅動系統 44 5.1簡介 44 5.2最大轉矩/安培控制 44 5.3弱磁控制 51 5.3.1基本原理 51 5.3.2自調式弱磁控制 58 第六章 系統研製 63 6.1簡介 63 6.2硬體電路 65 6.2.1功率級電路 66 6.2.2閘極驅動電路 66 6.2.3電流偵測電路 68 6.2.4過電流保護電路 69 6.2.5編碼器電路 70 6.2.6電源電路 71 6.2.7數位信號處理器 72 6.3軟體程式設計 75 6.3.1主程式 75 6.3.2中斷服務程式 76 第七章 實測 79 7.1簡介 79 7.2實測結果 81 第八章 結論與未來研究方向 98 參考文獻 99  

    [1] P. C. Sen, “Electric motor drives and control - past, present, and future,” IEEE Transactions on Industry Applications, vol. 37, no. 6, pp. 562-575, Dec. 1990.
    [2] P. Pillay and R. Krishnan, “Application characteristics of permanent magnet synchronous and brushless DC motors for servo drives,” IEEE Transactions on Industry Applications, vol. 27, no. 5, pp. 986-996, Sep./Oct. 1991.
    [3] S. I. Kim and G. H. Lee, “Design process of interior PM synchronous motor for 42-V electric air-conditioner system in hybrid electric vehicle,” IEEE Transactions on Magnetics, vol. 44, no. 6, pp. 1590-1593, June 2008.
    [4] S. Chi and Z. Zhang, “Sliding-mode sensorless control of direct-drive PM synchronous motors for washing machine applications,” IEEE Transactions on Industry Applications, vol. 45, no. 2, pp. 582-590, Mar./Apr. 2009.
    [5] K. W. Lee and S. Park, “A seamless transition control of sensorless PMSM compressor drives for improving efficiency based on a dual-mode operation,” IEEE Transactions on Power Electronics, vol. 30, no. 3, pp. 1446-1456, Mar. 2015.
    [6] K. Lu and P. O. Rasmussen, “A new low-cost hybrid switched reluctance motor for adjustable-speed pump applications,” IEEE Transactions on Industry Applications, vol. 47, no. 1, pp. 314-321, Jan./Feb. 2011.
    [7] K. Abbaszadeh and F. R. Alam, “On-load field component separation in surface-mounted permanent-magnet motors using an improved conformal mapping method,” IEEE Transactions on Magnetics, vol. 52, no. 2, Article # 5200112, Feb. 2016.
    [8] Q. Li and T. Fan, “Armature-reaction magnetic field analysis for interior permanent magnet motor based on winding function theory,” IEEE Transactions on Magnetics, vol. 49, no. 3, pp. 1193-1201, Mar. 2013.
    [9] Z. Yang and F. Shang, “Comparative study of interior permanent magnet, induction, and switched reluctance motor drives for EV and HEV applications,” IEEE Transactions on Transportation Electrification, vol. 1, no. 3, pp. 245-254, Oct. 2015.
    [10] G. Wang and J. Xu, “Weight-transducerless starting torque compensation of gearless permanent-magnet traction machine for direct-drive elevators,” IEEE Transactions on Industrial Electronics vol. 61, no. 9, pp. 4594-4604, Sep. 2014.
    [11] M. J. Melfi and S. D. Rogers, “Permanent-magnet motors for energy savings in industrial applications,” IEEE Transactions on Industry Applications, vol. 44, no. 5, pp. 1360-1366, Sep./Oct. 2008.
    [12] K. Kurihara and M. A. Rahman, “High-efficiency line-start interior permanent-magnet synchronous motors,” IEEE Transactions on Industry Applications, vol. 40, no. 3, pp. 789-796, May/June 2004.
    [13] T. Saito, “Magnetization process in Co-Zr-B permanent-magnet materials,” IEEE Transactions on Magnetics, vol. 40, no. 4, pp. 2919-2921, July 2004.
    [14] K. C. Kim and D. H. Koo, “A study on the characteristics due to pole-arc to pole-pitch ratio and saliency to improve torque performance of IPMSM,” IEEE Transactions on Magnetics, vol. 43, no. 6, pp. 2516-2518, June 2007.
    [15] H. S. Chen; D. G. Dorrell, “Design and operation of interior permanent-magnet motors with two axial segments and high rotor saliency,” IEEE Transactions on Magnetics, vol. 46, no. 9, pp. 3664-3675, Sep. 2010.
    [16] G. Y. Sizov and D. M. Ionel, “Modeling and parametric design of permanent-magnet AC machines using computationally efficient finite-element analysis,” IEEE Transactions on Industrial Electronics, vol. 59, no. 6, pp. 2403-2413, June 2012.
    [17] C. C. Hwang and Y. H. Cho, “Effects of leakage flux on magnetic fields of interior permanent magnet synchronous motors,” IEEE Transactions on Magnetics, vol. 37, no. 4, pp. 3021-3024, July 2001.
    [18] P. Alotto and M. Barcaro, “Optimization of interior PM motors with Machaon rotor flux barriers,” IEEE Transactions on Magnetics, vol. 47, no. 5, pp. 958-961, May 2011.
    [19] D. F. Chen and T. H. Liu, “Implementation of a novel matrix converter PMSM drive,” IEEE Transactions on Aerospace and Electronic Systems, vol. 37, no. 3, pp. 863-875, Feb. 2001.
    [20] F. Zidani and D. Diallo, “A fuzzy-based approach for the diagnosis of fault modes in a voltage-fed PWM inverter induction motor drive,” IEEE Transactions on Industrial Electronics, vol. 55, no. 2, pp. 586-593, Feb. 2008.
    [21] J. Y. Chai and Y. H. Ho, “On acoustic-noise-reduction control using random switching technique for switch-mode rectifiers in PMSM Drive,” IEEE Transactions on Industrial Electronics vol. 55, no. 3, pp. 1295-1309, Mar. 2008.
    [22] Z. Pan and R. A. Bkayrat, “Modular motor/converter system topology with redundancy for high-speed, high-power motor applications,” IEEE Transactions on Power Electronics, vol. 25, no. 2, pp. 408-416, Feb. 2010.
    [23] B. K. Bose, Modern “Power Electronics and AC Drive,” Prentice Hall PTR, New Jersey, 2002.
    [24] H. Liu and S. Li, “Speed control for PMSM servo system using predictive functional control and extended state observer,” IEEE Transactions on Industrial Electronics, vol. 59, no. 2, pp. 1171-1183, Feb. 2012.
    [25] S. Bolognani and L. Peretti, “Design and implementation of model predictive control for electrical motor drives,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1925-1936, June 2009.
    [26] J. L. Shi and T. H. Liu, “Adaptive controller design for a sensorless IPMSM drive system with a maximum torque control,” IEEE Proceedings - Electric Power Applications, vol. 153, no. 6, pp. 823-833, Nov. 2006.
    [27] M . N. Uddin and M. M. I. Chy, “A novel fuzzy logic controller based torque and flux controls of IPM synchronous motor,” IEEE Transactions on Industry Applications, vol. 46, no. 3, pp. 1220-1229, May/June 2010.
    [28] M. N. Uddin and T. S. Radwan, “Performance of interior permanent magnet motor drive over wide speed range,” IEEE Transactions on Energy Conversion, vol. 17, no. 1, pp. 79-84, Mar. 2002.
    [29] C. Mademlis and N. Margaris, Loss minimization in vector-controlled interior permanent-magnet synchronous motor drives,” IEEE Transactions on Industrial Electronics, vol. 49, no. 6, pp. 1344-1347, Dec. 2002.
    [30] V. Zivotic-Kukolj and W. L. Soong, “Iron loss reduction in an interior PM automotive alternator,” IEEE Transactions on Industry Applications, vol. 42, no. 6, pp. 1478-1486, Nov./Dec. 2006.
    [31] T. S. Kwon and G. Y. Choi, “Novel flux-weakening control of an IPMSM for quasi-six-step operation,” IEEE Transactions on Industry Applications, vol. 44, no. 6, pp. 1722-1731, Nov./Dec. 2008.
    [32] H. Liu and Z. Q. Zhu, “Flux-weakening control of nonsalient pole PMSM having large winding inductance, accounting for resistive voltage drop and inverter nonlinearities,” IEEE Transactions on Power Electronics, vol. 27, no. 2, pp. 942-952, Feb. 2012.
    [33] Y. Inoue and S. Morimoto “Comparative study of PMSM drive systems based on current control and direct torque control in flux-weakening control region,” IEEE Transactions on Industry Applications, vol. 48, no. 6, pp. 2382-2389, Nov./Dec. 2012.
    [34] J. M. Kim and S. K. Sul, “Speed control of interior permanent magnet synchronous motor drive for the flux weakening operation,” IEEE Transactions on Industry Applications, vol. 33, no. 1, pp. 43-48, Jan./Feb. 1997.
    [35] M. F. Rahman and Md. E. Haque, “Problems associated with the direct torque control of an interior permanent-magnet synchronous motor drive and their remedies,” IEEE Transactions on Industrial Electronics, vol. 51, no. 4, pp. 799-809, Aug. 2004.
    [36] P. Cortes and M. P. Kazmierkowski, “Predictive control in power electronics and drives,” IEEE Transactions on Industrial Electronics, vol. 55, no. 12, pp. 4312-4324, Dec. 2008.
    [37] S. Bolognani and S. Bolognani, “Design and implementation of model predictive control for electrical motor drives,” IEEE Transactions on Industrial Electronics, vol. 56, no. 6, pp. 1925-1936, June 2009.
    [38] A. Khlaief and M. Bendjedia, “A nonlinear observer for high-performance sensorless speed control of IPMSM drive,” IEEE Transactions on Power Electronics, vol. 27, no. 6, pp. 3028-3040, June 2012.
    [39] M. Preindl and E. Schaltz, “Sensorless model predictive direct current control using novel second-order PLL observer for PMSM drive systems,” IEEE Transactions on Industrial Electronics, vol. 58, no. 9, pp. 4087-4095, Sep. 2011.
    [40] M. Preindl and E. Schaltz, “Load Torque Compensator for Model Predictive Direct Current Control in High Power PMSM Drive Systems,” IEEE International Symposium on Industrial Electronics, pp. 1347-1352, July. 2010.
    [41] S. Morimoto and M. Sanada, “Wide-speed operation of interior permanent magnet synchronous motors with high-performance current regulator,” IEEE Transactions on Industry Applications, vol. 30, no. 4, pp. 920-926, July/Aug. 1994.
    [42] C. B. Butt and M. A. Hoque, “Simplified fuzzy-logic-based MTPA speed control of IPMSM drive,” IEEE Transactions on Industry Applications, vol. 40, no. 6, pp. 1529 - 1535, Nov./Dec. 2004.
    [43] M. N. Uddin and M. M. I. Chy, “Online parameter estimation based speed control of PM AC motor drive in flux-weakening region,” IEEE Transactions on Industry Applications, vol. 44, no. 5, pp. 1486-1494, Sep./Oct. 2008.
    [44] S. Bolognani and S. Calligaro, “Adaptive flux-weakening controller for interior permanent magnet synchronous motor drives,” IEEE Journal of Emerging and Selected Topics in Power Electronics vol. 2, no. 2, pp. 236-248, June 2014.
    [45] Texas Instruments, TMS320F28xxx Digital Signal Controllers, 2007.

    無法下載圖示 全文公開日期 2021/08/08 (校內網路)
    全文公開日期 本全文未授權公開 (校外網路)
    全文公開日期 本全文未授權公開 (國家圖書館:臺灣博碩士論文系統)
    QR CODE